Electronic tensile testing machine after entering the computer program to open the interface, according to the test, the weight of a standard weight is lighter than the upper fixture connecting block, the computer displayed strength values, and the difference between the calculation and the weight of the standard weight, the error should not exceed 0.5%.
Speed test of 2 electronic tensile testing machine
A. first recording machine crossarm of the initial position, select the speed value in the control panel (using standard straight ruler measurement arm stroke).
B. the starter at the same time, the electronic stopwatch to time a Z minutes, stopwatch time of arrival and press machine stop button, according to time stopwatch.
Recording transverse arm stroke value per minute rate (mm / min) were observed transverse arm stroke value and straight ruler of the poor, and calculate the cross arm stroke error value.
Should not exceed 1%.
If the speed or power of the electronic tensile testing machine is indeed a problem, it can be handled by the software. Or contact us, we will actively cooperate with you in the shortest time to handle the problem.