Electronic tensile testing machine, much like people, from time to time maintenance, to youth, vitality to stronger and prolong life of multi-functional electronic tensile machine, mainly divided into two parts host maintenance and control system maintenance
Main engine maintenance:
1, multi function electronic tensile machine with the fixture should be coated with anti rust oil storage;
2, due to the often used in the jaws of a hydraulic universal testing machine, easy to wear, oxidation skin too much, easily lead to leakage of small piston damage, so jaw should be cleaned regularly and kept clean (the best time to finish the test after cleaning);
3, insert plate and the lining plate is in contact with the sliding surface and lining board dovetail groove surface should be kept clean, coated with a thin layer of MoS2 (MoS2) grease on a regular basis.
Screw 4, regularly check the jaw position, if found loose, timely tightening;
5, regular inspection of the transmission of the sprocket wheel, if found loose, please re open the tension round;
Control system maintenance:
1, regular inspection of the controller of the multi - function electronic tensile machine panel of the connecting line is in good contact, if there is a loose, should be promptly tightened;
2, if there is a long time after the test without the machine, the controller and the computer shut down;
3, the controller on the interface for the one one, the wrong interface can be inserted into the device damage;
4, the plug on the interface must be shut off the controller power supply.
Electronic tensile testing machine